FLASH 4000
Automatic N/Protein Analyzers

 

 

 

The Flash 4000 N/Protein Analyzer provides the complete Nitrogen & N/Protein analysis packaging with enhanced productivity, innovative design and superior performance.

Building on more than 40 years of experience in Organic Elemental Analysis (OEA), Thermo
Fisher has developed the new generation FLASH 4000 which takes a "sample-in, results-out"
approach to ensure maximum ease-of-use and safety. Operating in a real-time, highly productive
manner and requiring minimum sample preparation, the analyzer decreases analytical costs and
increases revenues. The large sample size capacity of the FLASH 4000 ensures optimum
homogeneous analysis and results precision, reducing sample handling time and minimizing
matrix effects.


Design
• Foot print of 667 x 635 x 695 mm (w x d x h) or smaller
• All connections on the rear panel of the instrument


Operation
• Automatic operation and 125 sample capability which is able to handle more than 2 gram sample weight
• The analysis time will be 5 to 7 minutes depending on the sample nature.
• The analyzer is provided with a Thermal Conductivity Detector (TCD) which is able to measure Nitrogen in the range of 0.02 mg – 300 mg absolute
• Two calibration methods : K factor and Linear fit to ensure analytical condition stability


Combustion & Background
• Dual furnace system with catalyst based reactor
• The furnace should be ready for operation within 40 minutes after start-up from ambient temperature to operation temperature
• The catalyst will have a lifetime of more than 1000 analyses
• The analyzer should not have a gas split device


Regenerative CO2 adsorption filters
• Two carbon dioxide (CO2) filters (International Patent Pending) to increase the instrument autonomy and decreases the costs per analysis
• While one CO2 adsorption filter is used for the sample analysis, the other filter can be regenerated automatically


Oxytune® System
• Tailored Oxygen volume according to sample weight and sample nature
• The excess of oxygen is limited and increases the lifespan of reduction catalyst dramatically


Water Condensation Drainage System
• Removal of water out of the combustion gases, with a Peltier device, without the presence of a solid adsorber


Software
• Operating Xperience software supplied as standard
• Compatible with Windows VISTA and CFR21 part 11 compliance
• Select Nitrogen/Protein factors according to the typical food application
• Consider the humidity value in the final Nitrogen/Protein calculation
• Export data to LIMS and connection to LAN system
• Automatic leak test facility
• Control and check on maintenance status
• Start-up, standby and analytical cycle functions


Additional items to be available
• AS 3000 model Liquids auto sampler, with 120 sample vial positions